These
Cords are used for All types of Electrical Wires & Electronic Equipments
for Power Supplies. These electrical cables are manufactured as per Customer
Specification / Drawings. We are very reliable electrical wires and cables
manufacturers.
Miracle cables India pvt ltd believe in giving our
customers international quality materials. As a part of it miracle cables
started manufacturing UL certified cables in its plant at navi Mumbai. We
make style nos. 1015, 1007, 1569, 2129 and 2464. The product range is single
core, multi core with annealed bare copper and annealed tinned copper.
Temperature range is -30 to 105 deg cel. These cables come along with ROHS
and LF self declaration. Our UL file no. Is E307828.
Please find below details of the different styles of UL cables
| Company Name |
Category Name |
| MIRACLE CABLES (INDIA) PVT LTD |
Appliance Wiring Material - Component |
| MIRACLE CABLES (INDIA) PVT LTD |
Appliance Wiring Material Certified for Canada - Component |
| MIRACLE CABLES (INDIA) PVT LTD |
Wiring Harnesses - Component |
| MIRACLE CABLES (INDIA) PVT LTD |
Wiring Harnesses Certified for Canada - Component |
UL Style 1015
| S.No. |
AWG (Nom.Area) |
STRANDING |
NOM. INSUL. THICKNESS |
NOMINAL O.D. |
UL Style |
| 1 |
26 (0.128 mm²) |
7x34 (0.16mm) |
0.031"(0.76mm) |
0.818 (2.08mm) |
1015 |
| 2 |
24 (0.205 mm²) |
11x34 (0.16mm) |
0.031"(0.76mm) |
0.866 (2.20mm) |
1015 |
| 3 |
22 (0.324mm²) |
7 X 30 (0.254mm) |
0.031"(0.76mm) |
0.092" (2.33mm) |
1015 |
| 4 |
20 (0.519mm²) |
10 X 30(0.254mm) |
0.031"(0.76mm) |
0.100" (2.54mm) |
1015 |
| 5 |
18 (0.823mm²) |
16 X 30(0.254mm) |
0.031"(0.76mm) |
0.110" (2.79mm) |
1015 |
| 6 |
16 (1.31mm²) |
26 X 30(0.254mm) |
0.031"(0.76mm) |
0.122" (3.10mm) |
1015 |
| 7 |
14 (2.08mm²) |
41 X 30(0.254mm) |
0.031"(0.76mm) |
0.136" (3.45mm) |
1015 |
| 9 |
12 (3.31mm²) |
65 X 30(0.254mm) |
0.031"(0.76mm) |
0.159" (4.00mm) |
1015 |
| 10 |
11 (4.17mm²) |
82 X 30(0.254mm) |
0.031"(0.76mm) |
0.169" (4.30mm) |
1015 |
| 11 |
10 (5.26mm²) |
105 X 30(0.254mm) |
0.031"(0.76mm) |
0.183" (4.64mm) |
1015 |
| 12 |
9 (6.63 mm²) |
83x28 (0.318mm) |
0.031"(0.76mm) |
0.194" (4.94mm) |
1015 |
| 13 |
8 (8.36 mm²) |
105x28 (0.318mm) |
0.045"(1.15mm) |
0.257" (6.54mm) |
1015 |
| 14 |
7 (10.55 mm²) |
132x28 (0.318mm) |
0.045"(1.15mm) |
0.281" (7.15mm) |
1015 |
| 15 |
6 (13.30 mm²) |
167x28 (0.318mm) |
0.059"(1.52mm) |
0.336" (8.55mm) |
1015 |
| 16 |
5 (16.77 mm²) |
211x28 (0.318mm) |
0.059"(1.52mm) |
0.363" (9.24mm) |
1015 |
| 17 |
4 (21.15 mm²) |
266x28 (0.318mm) |
0.059"(1.52mm) |
0.391" (9.95mm) |
1015 |
| 18 |
3 (26.67 mm²) |
335x28 (0.318mm) |
0.059"(1.52mm) |
0.427" (10.87mm) |
1015 |
| 19 |
2 (33.62 mm²) |
423x28 (0.318mm) |
0.059"(1.52mm) |
0.452" (11.50mm) |
1015 |
| 20 |
1 (42.41 mm²) |
533x28 (0.318mm) |
0.079"(2.03mm) |
0.531" (13.50mm) |
1015 |
| 21 |
0 (53.40mm²) |
672x28 (0.318mm) |
0.079"(2.03mm) |
0.578" (14.70mm) |
1015 |
| 22 |
00 (67.43 mm²) |
848x28 (0.318mm) |
0.079"(2.03mm) |
0.634" (16.12mm) |
1015 |
| 23 |
000 (85.0 mm²) |
1070x28 (0.318mm) |
0.079"(2.03mm) |
0.692" (17.60mm) |
1015 |
| 24 |
0000 (107.2 mm²) |
1349x28 (0.318mm) |
0.079"(2.03mm) |
0.759" (19.30mm) |
1015 |
| Volts / Temperature |
600V, 221° F (105° C) |
| Insulation |
PVC Insulation Chemical, flame, and moisture resistant |
| Conductor |
Solid /Stranded, Tinned Copper, Bare Copper |
| Applications |
Used as internal wiring for appliances and electronic equipment |
| |
Note : Above conductor construction are Stranded conductor |
UL 1007 -
| S.No. |
AWG (Nom.Area) |
STRANDING |
NOM. INSUL. THICKNESS |
NOMINAL O.D. |
UL Style |
| 1 |
26 (0.128 mm²) |
7/0.16mm |
0.38 |
1.30mm |
1007 |
| 2 |
24 (0.205 mm²) |
11/0.16mm |
0.38 |
1.45mm |
1007 |
| 3 |
22 (0.324mm²) |
17/0.16mm |
0.38 |
1.60mm |
1007 |
| 4 |
20 (0.519mm²) |
21/0.18mm |
0.38 |
1.80mm |
1007 |
| 5 |
18 (0.823mm²) |
34/0.18mm |
0.38 |
2.10mm |
1007 |
| 6 |
16 (1.31mm²) |
26/0.254mm |
0.38 |
2.40mm |
1007 |
| Volts / Temperature |
300Vac, / 80° C |
| Insulation |
PVC Insulation Chemical, flame, and moisture resistant |
| Conductor |
Solid /Stranded, Tinned Copper, Bare Copper |
| Applications |
Used as internal wiring for appliances and electronic equipment |
| |
Note : Above conductor construction are Stranded conductor |